Home / ECE / Measurements and Instrumentation :: Section 6

ECE :: Measurements and Instrumentation

  1. The range of RTD using platinum is about

  2. A.
    -100° C to 700°C
    B.
    -200°C to 1000°C
    C.
    100°C to 1000°C
    D.
    about 500°C

  3. A digital voltmeter has a 4 1/2 digit display. The 1 V range can measure voltage up to

  4. A.
    0.9999 V
    B.
    1.9999 V
    C.
    0.199 V
    D.
    9.999 V

  5. Consider the following statements as regards induction and dynamometer wattmeters

    1. Dynamometer wattmeters can be used for dc only.
    2. Induction wattmeter has higher torque and dynamometer wattmeter.
    3. Induction wattmeter is less accurate, has more power consumption and more weight than dynamometer wattmeter.
    Which of the above statements are correct?

  6. A.
    1 only
    B.
    1 and 2 only
    C.
    2 and 3 only
    D.
    1 and 3 only

  7. A Maxwell's bridge has the unknown inductance in one arm and resistance in the other three arms.

  8. A.
    True
    B.
    False

  9. For a current transformer, the standard secondary rating is

  10. A.
    1 A or 5 A
    B.
    2.5 A
    C.
    10 A
    D.
    5 A or 10 A

  11. Assertion (A): When frequencies of signals fed to X and Y plates of CRO are multiples of each other, Lissajous pattern is displayed on screen.

    Reason (R): In a CRO, the vertical deflection is proportional to voltage applied to Y plates.

  12. A.
    Both A and R are true and R is correct explanation of A
    B.
    Both A and R are true but R is not correct explanation of A
    C.
    A is true R is false
    D.
    A is false R is true

  13. In portable instruments, damping is provided by

  14. A.
    spring
    B.
    gravity
    C.
    eddy current
    D.
    either (a) or (c)

  15. The sensitivity of electromagnetic digital flow meter can be increased by increasing

  16. A.
    circumferential width of rotor teeth
    B.
    radial depth of rotor teeth
    C.
    thickness of rotor teeth
    D.
    number of teeth

  17. The increase in intensity of trace in a CRO causes a change in

  18. A.
    beam current
    B.
    frequency of time base
    C.
    gain of Y amplifier
    D.
    accelerating voltage

  19. A diode peak reading VTVM and thermocouple meter are connected across output of an amplitude modulated circuit. In the absence of modulation both meters read 10 V. When sinusoidal AM is applied, VTVM reads 15V The reading of thermocouple meter will be

  20. A.
    10 V
    B.
    12.5 V
    C.
    14.1 V
    D.
    15 V